Water treatment plants, wastewater plants and pumping stations are run by SCADA systems and PLCs. Many stations are far away and reached over the mobile network. XoT protects them without you replacing the equipment.

Get startedRead about Hide and Protect

The situation

Why water and wastewater are especially exposed

The NIST draft of SP 800-82 Rev. 4 has its own section on water and wastewater. It points to the same risks that we see.

Scattered stations

Pumping stations, reservoirs and booster stations are spread out. They are often connected over the mobile network, radio links or leased lines.

Long service life

The control systems must work for many years. Many rarely get security updates, and some get none at all.

Vendors and service partners

Many smaller utilities let a vendor or service partner run their control systems. The contract often does not state clearly who is responsible for cybersecurity.

Water quality

The control systems dose chemicals and control treatment. An attack can affect water quality and people's health.

Read about NIST

Laws

Several laws apply to the same organisation

The examples below come from Sweden. Other EU countries have similar laws, because NIS2 and CER are EU directives.

NIS2

Drinking water and wastewater are sectors in NIS2. In Sweden the requirements apply through the Cybersecurity Act since 15 January 2026.

CER

Drinking water and wastewater are also part of CER, which is about resilience. Sweden is introducing CER through a new law.

Protective Security Act

Many water and wastewater utilities matter to Sweden's national security. Then the Swedish Protective Security Act also applies.

Confidentiality

Information about sites, control systems and networks may be confidential. This also applies to information in remote access systems.

Read about NIS2Read about CERRead about the Protective Security Act

Svenskt Vatten

The requirements in the security handbook and what XoT does

Svenskt Vatten, the Swedish water and wastewater association, has a security handbook for the sector. The handbook is not a law. It gathers requirements from laws and standards and adapts them to water and wastewater.

The table shows some of the handbook's requirements for control systems. The wording is our simplification. Rows where XoT helps are highlighted in green.

Requirement in the handbookWhat XoT doesXoT
External connections do not go directly into critical networksThe Lock only connects outbound. No inbound ports are opened, and access applies to one machine at a time.Yes
The network is divided so that faults and malware do not spreadOne Lock per device or group divides the network into smaller parts.Yes
Vendors do not reach critical networks without control, and their work is followed upAccess after approval and for a set time. Every connection is logged.Yes
No unauthorised connections from critical systems to the internetThe Lock can stop traffic out of the equipment.Yes
Encrypted traffic between subsystemsLock to Lock encrypts the traffic. Nothing changes in the equipment.Yes
Old control systems are protected until they are replacedHide and Protect makes the equipment invisible to anyone without an authorisation. It is a compensating control.Yes
Personal sign-in and access rights that are reviewedEach person has their own identity. The Policy Graph shows who can reach what. You do the review.Partly
Logs that are protected against changes and reviewedThe XMS logs every connection and every policy change. Logs can be sent to your SIEM. You do the review.Partly
Alarms when communication changes abnormallyThe Lock can send a copy of the traffic to an intrusion detection system. XoT does not raise alarms itself.Partly
Operation without the network, and manual operation that is practisedThis is work in your organisation.No

Svenskt Vatten (in Swedish)

Remote stations

Protect pumping stations and other remote stations

A pumping station is connected to the SCADA system. From the station, it is often possible to reach other parts of the process. That makes the stations a possible way in for an attacker.

Two sites, each with a Lock in front of the equipment. The Locks have an encrypted connection with each other over the internet.
The Lock in the station and the Lock at the SCADA system have an encrypted connection between them.

A Lock in every station

The Lock sits between the station's equipment and the network. The equipment becomes invisible to anyone without an authorisation.

Encrypted connection to the SCADA system

The Lock in the station has an encrypted connection to a Lock at the SCADA system. Nothing is installed in the station's equipment or in the SCADA system.

Only the traffic that is needed

A policy in the XMS decides which traffic may pass between the station and the SCADA system. The stations cannot reach each other unless a policy allows it.

Works over mobile networks

XoT works over any IP network, including mobile networks. The Lock can also be installed directly in Teltonika routers.

Read about XoT on TeltonikaRead about micro-segmentation

Vendors

Give the vendor access to the right station

Without XoT

The vendor connects to the operations network over VPN. From there, many stations can often be reached. If the vendor is attacked, the attacker can reach them too.

With XoT

The vendor gets access to specific equipment for a set time. An operator can approve each connection. Everything is logged.

A service partner can run the XMS for several smaller utilities. Each utility sees only its own equipment.

Read about access approvalOperations and support centres

Where XoT runs

Information about your sites stays with you

The XMS holds information about your equipment and your policies. Such information may be confidential or need protective security.

That is why all of XoT can run under your own control, in your own data centre or fully separated from the internet. XoT is developed in Sweden, and the XoT-S1 hardware is designed and manufactured in Sweden.

Read about the architectureRead about the XMS

Common questions

Can we start with one pumping station?

Yes. A Lock in the station and a Lock at the SCADA system are enough to start. Then you can add more stations.

Do we have to rebuild the network?

No. The Lock sits in front of the equipment, and the equipment does not need to change.

Does XoT replace backup and manual operation?

No. Critical functions must be able to run without the network. That is work in your organisation.

Is XoT enough to comply with NIS2?

No. XoT helps with several of the measures, but the law requires more. We have gone through which ones.

See the NIS2 review

What we write about laws and the security handbook is our interpretation. It is not legal advice.

Start with one station